Key takeaways
- Plug the probe into the marked temperature or standard inputs, per the manual, and select the temperature function before touching the probe to anything.
- Never connect the thermocouple probe to a live circuit. Fluke’s manual for the 179 warns not to connect the 80BK probe to live circuits, and Klein’s MM700 manual says to remove the thermocouple before switching to other functions. Do the same on any meter.
- Give the probe time to settle; thermocouple readings lag, especially on thicker surfaces.
- Place the tip against a clean surface for good contact; insulating tape or heat paste can improve contact, but follow the probe maker’s instructions.
- For hot or high-temperature objects, use a probe rated for the temperature, and keep the meter body away from the heat. Operating limits for the meter body are separate; the Fluke 179 lists -10 to 50 degrees Celsius for operation.
A multimeter with a temperature sensor is a digital multimeter that reads a thermocouple probe, usually type K, alongside voltage, current and resistance, and the clearest current picks are the Fluke 179 for a bench and field all-rounder, the Klein Tools MM720 for an electrician who wants temperature and a high voltage rating, and the Fluke 87V for industrial users who need the widest range. If you also need to measure current on large wires without breaking the circuit, the Fluke 325 and Klein Tools CL390 clamp meters add temperature to a clamp body.
Why add temperature to a multimeter?
Temperature readings help you find hot connections, check heating and cooling system output, judge whether a motor or transformer is running warm, and confirm that a refrigerator or freezer is cooling. A thermocouple probe touches the surface or sits in the air or liquid you are checking, and the meter converts the tiny voltage the probe produces into degrees. This is a contact measurement; it is not the same as an infrared thermometer, which reads surface temperature from a distance.
At a glance
| Model | Best for | Stated temperature details | Other stated points | Limits |
|---|---|---|---|---|
| Fluke 179 | General electrical and HVAC work | -40 to 400 degrees Celsius; 1.0 percent plus 10 counts; 0.1 degree resolution; included 80BK probe, type K | True-rms; 1000 V AC/DC and 10 A AC/DC; Min/Max/Average; CAT III 1000 V and CAT IV 600 V | Included probe is meant for lower temperatures than the meter range |
| Fluke 87V | Industrial and electronics work | Meter range -200 to 1090 degrees Celsius excluding probe; included 80BK covers -40 to 260 degrees Celsius | Industrial multimeter; Min/Max/Average; CAT III 1000 V and CAT IV 600 V; operating temperature -20 to 55 degrees Celsius | Premium tier; larger and heavier than the mid-range meters |
| Klein Tools MM720 | Electricians who want temperature with LoZ | -40 to 1832 degrees Fahrenheit (-40 to 1000 degrees Celsius) as the maker lists; included thermocouple rated to 356 degrees Fahrenheit (180 degrees Celsius) | TRMS, auto-ranging, 1000 V, 6000 counts, MAX/MIN, low-impedance mode | Included probe limits real-world range unless you buy a higher-rated one |
| Fluke 325 clamp | Clamp-style current plus temperature | -10 to 400 degrees Celsius with included K-type thermocouple | 400 A AC/DC; CAT III 600 V | Fewer meter functions than a full multimeter |
| Klein Tools CL390 clamp | Clamp-style with non-contact voltage | Thermocouple temperature function; check Klein’s spec sheet for the exact range | 400 A AC/DC; 4000 counts | Clamp body, lower category than the MM720 |
The older MM700 has been superseded by the MM720, so choose the MM720 rather than hunting for old stock.
What to compare
Probe rating versus meter range
The meter range and the probe range are different things. The Fluke 87V’s meter range reaches 1090 degrees Celsius excluding the probe, but the included 80BK probe is listed to 260 degrees Celsius. Klein’s MM720 lists a wide meter range but its included thermocouple is rated to 180 degrees Celsius, and Klein says to use an appropriately rated thermocouple for higher temperatures. Pick the probe for the job, not only the meter.
Accuracy statement
Fluke lists the 179’s temperature accuracy at 1.0 percent plus 10 counts, which does not include the probe’s own error. A typical probe’s tolerance adds to that, so a stated number such as 1 percent plus 10 counts is a floor, not the real-world result.
Resolution and display
0.1 degree resolution helps with small changes, such as comparing supply and return air. Larger count displays, such as the 6000 counts on the MM720, give finer readings on other functions too.
Safety category
Fluke lists CAT III 1000 V and CAT IV 600 V for the 179. Match the category to where you will work; do not use a meter above its stated rating.
Min/Max recording
Many technicians want temperature to be recorded over time. Min/Max/Average on the 179 and MAX/MIN on the Klein MM720 help catch peaks without staring at the display.
Using the temperature function correctly
- Plug the probe into the marked temperature or standard inputs, per the manual, and select the temperature function before touching the probe to anything.
- Never connect the thermocouple probe to a live circuit. Fluke’s manual for the 179 warns not to connect the 80BK probe to live circuits, and Klein’s MM700 manual says to remove the thermocouple before switching to other functions. Do the same on any meter.
- Give the probe time to settle; thermocouple readings lag, especially on thicker surfaces.
- Place the tip against a clean surface for good contact; insulating tape or heat paste can improve contact, but follow the probe maker’s instructions.
- For hot or high-temperature objects, use a probe rated for the temperature, and keep the meter body away from the heat. Operating limits for the meter body are separate; the Fluke 179 lists -10 to 50 degrees Celsius for operation.
Safety notes
- Follow the manual for your exact model and use only the leads and accessories it names.
- Voltage and current measurements on building wiring should respect local code. Hardwired work, panel work and anything involving the service entrance belongs to a licensed electrician.
- Do not bypass fuses or protection devices inside the meter, and replace a blown fuse only with the type the maker specifies.
- For heating equipment, boilers and gas appliances, a temperature reading is only data; service and repairs should be done by a qualified technician following the appliance maker’s instructions.
Budget, mid-range and premium tiers
- Budget: entry multimeters with a temperature function exist, but the ones named in this guide are above that tier. If you choose a budget meter, look for a listed category, a type K input and a probe that suits your range.
- Mid-range: Klein Tools MM720, Fluke 179, and the clamp meters Fluke 325 and Klein CL390.
- Premium: Fluke 87V for demanding industrial use and the widest range.
Pick-by-need decision table
| If you … | Choose |
|---|---|
| Want a trusted all-round field meter with an included probe | Fluke 179 |
| Need low-impedance mode and a wide meter range | Klein Tools MM720 |
| Work in industrial settings with broad temperature needs | Fluke 87V |
| Need to measure large currents and temperature with one tool | Fluke 325 or Klein Tools CL390 |
Alternatives
- Infrared thermometer. Measures surface temperature from a distance. It is faster but reads emissivity-dependent surfaces less reliably, so it complements a contact probe.
- Dedicated thermocouple thermometer. Better when temperature is your main job, such as in HVAC or food service.
- Thermal imaging camera. Shows hot spots across a panel or motor, though it costs far more than a meter.
Choosing a probe for the job
- Air and liquid checks. A general-purpose bead or immersion thermocouple suits supply and return air or liquids. The 80BK probe included with Fluke’s meters is described for general use within its listed range.
- Surface contact. A flat or surface probe gives faster, steadier readings on pipes, motors and terminals than a loose bead.
- High temperatures. Klein’s manual says to use an appropriately rated thermocouple above the included probe’s 356 degrees Fahrenheit limit. Do not assume the meter range equals the safe probe range.
- Keeping the meter cool. The meter body has its own operating range, for example -10 to 50 degrees Celsius on the Fluke 179, so hold the meter away from the hot object and use the probe lead for reach.
Thermocouple readings also depend on the meter’s reference junction, which is why readings can drift if the meter has just moved from a cold truck to a warm room. Give the meter a few minutes to settle to room temperature before relying on a precise number.
Frequently Asked Questions
What type of probe do these meters use?
The Fluke 179 and the Fluke 325 use a type K thermocouple. Klein includes a thermocouple with the MM720 and lists a thermocouple temperature function on the CL390. Always match the probe type to the meter’s input as the manual states.
Can I measure the temperature of a live wire?
Do not connect a thermocouple probe to a live circuit. A probe that touches a live conductor can introduce a hazard to the meter and user. Read the manual’s warning and use a non-contact method such as an infrared thermometer where suitable.
Why is the included probe limited to a lower temperature than the meter?
Probe construction limits the safe range. The meter can read up to a higher range, but a standard bead or insulated probe is built for typical service temperatures. Choose an appropriately rated probe for furnaces or kilns.
Is the Klein MM700 still sold?
It has been superseded by the MM720, so prefer the MM720 for a new purchase.
Do I need a multimeter or a clamp meter?
A multimeter is better for voltage, resistance and small current, while a clamp is better for larger current without breaking a circuit. Several users own both, and models like the Fluke 325 combine clamp and temperature.
How accurate are the temperature readings?
The stated accuracy excludes the probe. For the Fluke 179 it is 1.0 percent plus 10 counts, and the probe’s own tolerance adds on top. For critical measurements, use a calibrated thermometer and the maker’s guidance.
Keep reading