Key takeaways
- Plug-in energy meter or smart plug (consumer). Sits between a wall socket and an appliance and reports volts, amps, watts and kilowatt-hours. This is the most useful reading for a home buyer.
- Three-phase power and energy logger (professional). Clamps or probes onto a panel or feeder and records voltage, current, harmonics and energy over days. These are tools for electricians and energy auditors.
- Other power meters. A bicycle power meter measures pedal power, and an optical power meter measures light in a fibre. They are covered by separate guides.
“Portable power meter data logger” most often means a device that measures electrical power and energy use and keeps a record, and for a home buyer the realistic choices are a plug-in energy monitor such as the P3 Kill A Watt or a smart plug such as the Shelly Plug US Gen4, while the Fluke 1736 and 1738 are professional three-phase power loggers that a household buyer would not normally purchase. Two other meanings exist, a cycling power meter and an optical power meter, and this guide names the electrical meaning first.
Our top picks
As an Amazon Associate we earn from qualifying purchases at no extra cost to you.
Three things the keyword can mean
- Plug-in energy meter or smart plug (consumer). Sits between a wall socket and an appliance and reports volts, amps, watts and kilowatt-hours. This is the most useful reading for a home buyer.
- Three-phase power and energy logger (professional). Clamps or probes onto a panel or feeder and records voltage, current, harmonics and energy over days. These are tools for electricians and energy auditors.
- Other power meters. A bicycle power meter measures pedal power, and an optical power meter measures light in a fibre. They are covered by separate guides.
At a glance
| Model | Best for | Stated details | Limits |
|---|---|---|---|
| P3 Kill A Watt P4400 | Checking how much an appliance uses over a day or week | Plug-in meter; shows volts, amps, watts, hertz and VA; power factor and line quality readings; counts kWh from the moment power is applied, from 0.01 up to 9999 kWh; accuracy listed as 0.2 percent by the maker (some listings give a wider 0.2 to 2.0 percent band); 115 V AC, up to 15 A and 1875 VA | The maker describes cumulative kWh and elapsed time, not a time-stamped log; for 120 V North American outlets |
| P3 Kill A Watt EZ (P4460) | Same use with battery backup | Adds built-in battery backup and cost forecasts by week, month and year | Still a single-appliance plug-in meter |
| Shelly Plug US Gen4 | Smart plug with metering and app control | Up to 15 A (1800 W resistive); 120 V at 60 Hz; own draw under 1.5 W; voltage, current, power and energy metering; internal temperature sensor; Wi-Fi, Zigbee and Bluetooth; Matter-certified | 1800 W applies to resistive loads only; history depends on the connected app or platform |
| Fluke 1736 / 1738 | Professional power-quality and energy logging | Four voltage inputs (three phases plus neutral) to 1000 V rms; current via flexible probes, with an optional thin probe covering up to 6000 A; Li-ion battery with about four hours standard runtime as the maker lists | Professional tool; the 1738 adds triggered waveform recording of voltage and current |
Shelly has also sold older plugs, such as the Shelly Plus Plug US, which the Gen4 plug now supersedes; for a new purchase, look at the Gen4 plug on the maker’s page and leave older stock alone. The Kill A Watt family also includes a Connect model with a separate plug and display housing joined by a cable, and a Control model that combines monitoring with an automatic timer.
What “data logger” really means in a plug-in meter
A basic plug-in monitor accumulates energy since it was plugged in, which is a total, not a graph over time. That is often enough to answer the question “how much does this freezer use per month”. If you want a record of how power changed through the day, you need a meter that stores or reports readings over time, such as a smart plug that sends metering data to an app, or a professional logger. The maker’s listings for the Shelly plug name voltage, current, power and energy metering; how long history is kept depends on the app or home automation platform you connect, so read the maker’s documentation for the platform you use.
Compatibility and electrical limits
Plug type and voltage
The Kill A Watt P4400 is rated at 115 V AC with 125 V maximum, which means North American 120 V outlets. The Shelly Plug US Gen4 is specified at 120 V and 60 Hz. Equipment made for other mains standards needs a model made for that region.
Load limits
The Kill A Watt lists up to 15 A and 1875 VA. Shelly lists 15 A and 1800 W, and notes that the 1800 W figure applies to resistive loads. Heaters, kettles and air conditioners can approach those limits, so check the nameplate of the appliance and keep it inside the meter’s rating.
Motor and electronic loads
Loads with large starting currents, such as compressors, may pull more than their running current for a moment. Read the manual of the meter, and do not connect a load above the meter’s stated rating.
Whole-home monitoring
Monitoring a whole house means working at the service panel, with current sensors on the main conductors. That is a hardwired or panel job; follow the product manual and local code, and hire a licensed electrician if the work involves opening a panel.
Safety notes
- Use only equipment with a safety listing that the maker states, and follow the manual.
- Never use a plug-in meter on an extension cord or power strip that is already near its limit.
- Do not cover a meter or smart plug during use; the heat from the load and the meter itself needs airflow.
- Do not use a plug-in meter in wet locations unless the maker lists it as suitable.
- Do not open a panel, add a sensor to a service conductor or modify wiring unless you are qualified. This is licensed electrician work under local code.
- A smart plug that switches a heater or similar appliance should be used within the maker’s limits, and does not replace a thermostat or built-in safety controls.
Budget, mid-range and premium tiers
- Budget: basic plug-in energy monitors such as the Kill A Watt P4400, aimed at single-appliance checks.
- Mid-range: smart plugs with app history and automation, such as the Shelly Plug US Gen4, and the Kill A Watt EZ and Connect variants.
- Premium: professional three-phase loggers such as the Fluke 1736 and 1738 with clamps and flexible probes.
Pick-by-need decision table
| If you … | Choose |
|---|---|
| Want to know how much one appliance uses per month | Kill A Watt P4400 |
| Want battery backup so totals survive an unplug | Kill A Watt EZ |
| Want metering plus app control and smart-home integration | Shelly Plug US Gen4 |
| Are an electrician or energy auditor logging a three-phase feeder | Fluke 1736 or 1738 |
| Need a clamp meter that records min, max, average and inrush | Fluke 376 FC (see the clamp meter guides) |
The professional option in more detail
Fluke lists the 1736 and 1738 as three-phase power quality loggers. They log rms voltage and current, events, total harmonic distortion, harmonics to the 50th, power, power factor and energy. Compliance is listed as IEC 61000-4-30 Class S. Voltage inputs are rated to 1000 V rms, the enclosure is listed as IP50, and current is measured with flexible probes, with an optional thin probe for the largest ranges up to 6000 A. Because it is connected to live conductors at distribution level, installation is for qualified persons following the maker’s manual and local rules.
Getting useful numbers from a plug-in meter
- Run the appliance through a full cycle. A washing machine needs at least one complete cycle, and a refrigerator or freezer needs a day or more, so the total includes compressor stops and defrost.
- Note the date and starting reading, then divide the total kilowatt-hours by the elapsed time to get a daily average.
- Compare standby draw by leaving a device switched off at the unit but still plugged in, as many electronics draw a small amount continuously.
- Multiply kilowatt-hours by your utility’s rate to estimate running cost. Rates differ by region and time of day, so use the figures on your own bill.
The Kill A Watt materials describe forecasting cost by day, week, month or year from the readings, and the EZ variant adds weekly and monthly forecasts, so the arithmetic is built in. For smart plugs, the app or platform you connect decides how that history is displayed.
Frequently Asked Questions
Does the Kill A Watt log usage over time?
The maker describes cumulative kilowatt-hours and elapsed time since power was applied. It does not describe a time-stamped history, so use it for totals rather than a graph.
Can a smart plug show power history?
The Shelly Plug US Gen4 lists power and energy metering. How the history is stored and displayed depends on the app or platform you connect it to.
Can I plug a space heater into these meters?
Only if the heater’s rating fits within the meter’s. Shelly lists 1800 W for resistive loads at 15 A, and the Kill A Watt lists 15 A and 1875 VA. Many heaters use close to that maximum, so read the nameplate and the manual first, and do not use a meter or plug with a lower rating than the appliance.
Is a three-phase logger useful at home?
Almost never. Most homes use single-phase supply and do not need a logger like the Fluke 1736. Light commercial and industrial buildings are where such tools are used by professionals.
Do these meters work on 230 V appliances?
The Kill A Watt P4400 and Shelly Plug US Gen4 are specified for 120 V outlets. For 230 V regions, use a model made and listed for that standard.
How accurate is a plug-in energy meter?
The maker states 0.2 percent accuracy for the Kill A Watt P4400, though some listings give a wider band. Real-world results vary with load type, so use readings as a guide for comparing appliances, not for billing disputes.